Home/Walls & Finishes/Brandered Ceiling Calculator

Brandered Ceiling Calculator

RhinoBoard, branders and screws for a ceiling. Metric units, change any unit beside its field.

Measurements

The branders size follows this spacing.
%
Extra for cuts, breakage and spillage.

About this calculator

Takeoff for a brandered RhinoBoard ceiling: boards, timber branders at the right size and centres, and screws.

How it’s calculated

Branders are nailed under the trusses or joists, at 90° to them. Gyproc sets their centres by ceiling type: 400 mm for 6.4 mm M-strip ceilings, 300 mm for 6.4 mm flush plastered, 500 mm for 9.5 mm flush jointed and 400 mm for 9.5 mm flush plastered. Brander size follows the truss spacing: 38 × 38 mm up to 1,000 mm, 38 × 50 mm up to 1,200 mm and 50 × 75 mm up to 1,400 mm; beyond that, consult an engineer. Boards are 1,200 mm wide.

Worked example

With these inputs:

Room length
6 m
Room width
4.8 m
Ceiling
RhinoBoard 6.4 mm, M-strip jointed (branders at 400 mm)
Truss or joist spacing (mm)
1000
Board length
3,000 mm
Waste allowance
5%

the result is:

RhinoBoard sheets
9 sheets
Ceiling area
28.8 m²
Brander rows
13 at 400 mm centres
Brandering
81.9 lin m
Brander size for 1000 mm truss spacing
38 × 38 mm

Tips from the trade

  • Level the branders from the lowest point, packing with wedges where needed.
  • Fix light fittings to the branders, not to the RhinoBoard.

Results are estimates for planning and pricing. Check quantities against your drawings, the manufacturer’s data and SANS 10400 (the National Building Regulations) and your local municipality before ordering.